Fireplace safety your tenants never have to think about
Scheduling a building
Use the form to list each address and how many fireplaces it has. We call back to plan the visit around your tenants.
The safety items we check in every unit
A tenant lights a fireplace without knowing what is behind it. Our check is built around what could hurt them, in the order it matters, and every unit is marked against the same list.
California law puts carbon monoxide alarms on the owner's list in homes with a fuel-burning appliance. We note whether one is present near the fireplace; testing and replacing alarms stays with the owner or manager.
- Smoke or fumes coming back into the room: a blocked flue, a damper that will not open, a cracked firebox
- Carbon monoxide from gas units: soot marks, a poor flame, a vent that does not draw
- Heat reaching wood: gaps in the lining, a mantel or trim set too close to the opening
- Traces of a past chimney fire: burnt deposits, warped dampers, heat-stained caps
- Pieces that could come down: a broken crown or a cap working loose
Which units need the camera
Most units only need the visual check, $57 per fireplace. It looks at the opening, the firebox, the damper, the hearth and as much of the lower flue as a torch shows, and it suits a building where nothing has changed since the last round.
A unit moves up to a Level 2, $410, when a tenant reports smoke in the room, a roar or a burning smell from the flue, or when the visual check finds signs of an earlier fire. The camera goes the full height of that flue, and the unit's page says why it was needed.
What the record looks like
Each fireplace gets its own dated page: unit number, what was checked, what was found, photos, and one of three outcomes: safe to use, keep out of use until fixed, or fix soon. A unit marked out of use comes with a short note you can hand the tenant explaining why the fireplace is off limits until the repair.
The building summary lists every unit on one sheet, so a manager or a board can see at a glance which fireplaces are cleared and which are waiting on work. Where a flue needs sweeping, that is priced per flue, from $435.
Priced per fireplace
Figures below are for a single fireplace. A building's total is the sum of its units.
- Safety check, one fireplace, no camera
- $57
- Camera survey of one flue after smoke or fire signs
- $410
- Sweeping one flue
- from $435
Repairs found in a unit are written up for that unit, so the cost lands with the right owner or account.
Questions from managers and boards
Do you check gas fireplaces as well?
Yes. On gas units we look at the flame, the pilot area, soot marks and whether the vent draws. Anything that points to a carbon monoxide risk is marked out of use until fixed.
What happens when a unit fails?
That fireplace is marked out of use on its page, with the reason and photos. The repair is written up for that unit alone.
A tenant says the fireplace smells of smoke. How serious is that?
Treat it as out of use until checked. Smoke in the room means fumes are not leaving the way they should. Put that unit first on the visit.
Can the records go to our insurer or the board?
Yes. List the board secretary or the insurer on the booking; the summary sheet and the unit pages go to each.
Does every unit need the camera?
No. The camera is for units with a reason: smoke, fire signs or damage seen on the visual check.
Get every fireplace on record
Use the contact page to list the buildings and their fireplaces. We plan the visit around your tenants.